Repeatable Temperature Profiles on every component processed
Inert or Reducing Process Atmospheres
Model
2BF
4BF
6BF
8BF
Usable Hot Zone
2" (5cm) W
.5" (1.3cm) H
8" (20cm) L
4" (10.2cm) W
.62" (1.6cm) H
8" (20cm) L
6" (15.2cm) W
1" (2.5cm) H
36" (91cm) L
8" (20cm) W
1" (2.5cm) H
*48"-72"
Maximum Temp.
Tungsten Hot Zone
Graphite Hot Zone
2000°C
2300°C
2000°C
2300°C
2000°C
2300°C
2000°C
2300°C
Belt Speed
Range
.2"/min
20"/min.
.2"/min
20"/min.
.1"/min
5"/min.
.1"/min
5"/min.
Process Gas Flow+
14 LPM
28 LPM
70 LPM
90 LPM
Elect. Req. KVA
Inert
H2
25
30
30
35
120
150
200x
240
Water Req.
GPM (LPM)
7
(19)
9
(34)
35
(133)
55
(207)
Floor Space
Feet ( m)
4' x 10'
(1.2 x 3.1)
4' x 10'
(1.2 x 3.1)
5' x 14'
(1.5 x 4.2)
6' x 16'
(1.8 x 4.9)
Model
44BF
66BF
124BF
Usable Hot Zone
4" (10cm) W
4" (10cm) H
*36"-96"
6" (15cm) W
6" (15cm) H
*36"-36"
12" (30cm) W
4" (10cm) H
*36"-96"
Maximum Temp.
Tungsten Hot Zone
Graphite Hot Zone
2000°C
2300°C
2000°C
2300°C
2000°C
2300°C
Belt Speed
Range
.1"/min
5"/min.
.1"/min
5"/min.
.1"/min
5"/min.
Process Gas Flow+
140 LPM
160 LPM
220 LPM
Elect. Req. KVA
Inert
H2
200x
240
240x
300
350x
N/A
Water Req.
GPM (LPM)
55
(207)
68
(256)
80
(303)
Floor Space
Feet ( m)
6' x 16'
(1.8 x 4.9)
6' x 16'
(1.8 x 4.9)
7' x 16'
(2.1 x 4.9)
* The hot zone length is customized to suit production requirements
+ Process gases of Argon, Nitrogen, Hydrogen and Helium are utilized x Power is appropriate for shortest hot zone length listed